Omron-Automation Module PLC Programmable Controller (CPM2A-60CDR-D)

Omron-Automation Module PLC Programmable Controller (CPM2A-60CDR-D)

Category: ELECTRICAL CONTROL

Specifications
Details



Model :
  • CPM2A-60CDR-D
 

Features :
 
  • Interrupt Inputs – Triggered when inputs 00003–00006 change OFF → ON; use subroutines 000–003.
  • Interval Timer Interrupt – Executes interrupts with 0.1 ms precision; subroutines 000–049 can be assigned.
  • Count-up Interrupt – Inputs 00003–00006 count pulses up to 2 kHz; interrupt occurs when count reaches SV.
  • Count-check Interrupt – High-speed inputs 00000–00002 count up to 20 kHz or 5 kHz; interrupt occurs when PV = target value or within range.
  • Interval Timer (CPM2) – One timer, 0.5 ms – 319,968 ms range, 0.1 ms precision, supports single or scheduled interrupts.
  • High-speed Counter – Built-in counter up to 20 kHz; supports target or range comparison independent of PLC cycle time.
  • Pulse Outputs – Two outputs supporting single-phase pulses, variable duty pulses, or trapezoidal acceleration/deceleration.
  • PV Coordinate System – Can be set to relative or absolute in PLC setup.
  • Synchronized Pulse Control – Combines high-speed counter + pulse output to generate pulses 10 Hz – 10 kHz proportional to input frequency.
 

Dimension :



 

Specifications :
 
Item CPU Units with
20 I/O points
CPU Units with
30 I/O points
CPU Units with
40 I/O points
CPU Units with
60 I/O points
Supply voltage AC power 100 to 240 V AC, 50/60 Hz
DC power 24 VDC
Operating voltage range AC power 85 to 264 V AC
DC power 20.4 to 26.4 V DC
Power consumption AC power 60 VA max.
DC power 20 W max. 
Inrush current AC power 60 A max.
DC power 20 A max.
External power supply
(AC power supplies only)
Supply voltage 24 VDC
Output capacity 300 mA
Insulation resistance 20 ΜΩ min. (at 500 V DC) between the external AC terminals and protective earth terminals
Dielectric strength 2,300 V AC 50/60 Hz for 1 min between the external AC and protective earth terminals, leakage current: 10 mA max.
Noise immunity Conforms to IEC61000-4-4, 2 kV (power lines)
Vibration resistance 10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s² in X, Y, and Z directions for 80 minutes each
(Time coefficient; 8 minutes x coefficient factor 10 = total time 80 minutes)
Shock resistance 147 m/s² three times each in X, Y, and Z directions
Ambient temperature Operating: 0° to 55°C
Storage: -20° to 75° C
Humidity 10% to 90% (with no condensation)
Atmosphere Must be free from corrosive gas
Terminal screw size M3
Power interrupt time AC power supply: 10 ms min.
DC power supply: 2 ms min.
CPU Unit weight AC power 650 g max. 700 g max. 800 g max. 1,000 g max.
DC power 550 g max. 600 g max. 700 g max. 900 g max.
Expansion Unit weight Units with 20 I/O Points : 300 g max.
Units with 8 Output Points : 250 g max.
Units with 8 Input Points : 200 g max.
MAD01 Analog I/O Unit : 150 g max.
MAD11 Analog I/O Unit : 250 g max.
AD041/DA041 Analog I/O units : 200 g max.
Temperature Sensor Units : 250 g max.
CompoBus/S I/O Link Units : 200 g max.
DeviceNet I/O Link Unit : 200 g max.
PROFIBUS-DP I/O Link Unit : 150 g max.
 


 

View more about Omron-Automation Module PLC Programmable Controller (CPM2A-60CDR-D) on main site