Punching Machine Safety Light Curtain

Punching Machine Safety Light Curtain


Specifications
Details




ESA series is mainly used for safety protection for stamping machinery, which adopt controller to monitor and output signal of light curtains.
ESA series supports AV110-220V, AC380V voltage and output relay signal. ESA series is designed according to EU safety standard, whose main components are imported.
Good self-diagnosis, easy to operation, and strong anti-vibration ability make ESA series can work in different hazardous equipment, and well protect operators from accident.

 



Model :
 






 


Features :
 
  • AC110V-220V, AC380V wide voltage for stamping machinery;
  • Controller reliably monitor signal of light curtain by pulse detection method, which effectively ensure that mistake signal will not be triggered when short circuit;
  • Good performance to against electromagnetic interference of different machine motor;
  • Anti-shock circuit and strong aluminum alloy enclosure well against vibration;
  • Wire-syn good to against light interference;
  • Controller output signal by relay isolation output mode, and the external control signal is completely isolated form internal circuit of barriers;
  • Plug connecting between curtain & controller make wire connection easily and quickly,
  • Multiple brackets for various environment mounting;
  • One controller can work with more sets of safety light curtain for multi-faced protection;
  • Long sensing distance up to 20m.

 


Applications :



 

Dimension :




 


Wire Diagram :

  • External Controller (P-Type)
    • L (brown) and N (blue) is input wire of AC110V/220V, please check and ensure right connection;
    • T (brown) and K (blue) should be connected with control circuit of machine shown as below. When beams are through, T&K are connected and the machine works well; When beams are blocked, T&K are disconnected to stop the machine.

  • Internal Controller (Q)
    • Connection of T.K wire, under normal circumstance, Return No Protection no need);
    • Connection of T.K (need Return No Protection), Return No Protection function is usually achieved by machine, no need to connect additionally.
    • When it needs to be achieved by safety light curtain, you can connect wire as below method.
    • A pair of normally open contacts of the cam are connected in parallel with Tand K.

 

Specifications :
 

Controller Electric Parameter
Power Supply AC110V-220V 50/60Hz, AC380V
Capacity < 15W
Output Relay contact output
Contact Capacity 5A, AC250V/DC30V Resistive load
Relay lifespan ≥10 million times, electrical life is depend on the connected load, can be changed;
Response Time ≤20ms
Amblent Temperature -10-55°C No freezing
Ambient Humidity 20°C, RH ≤ 85%
Insulation Resistance ≥ 100ΜΩ
Protection Rate P controller: IP54 Q controller: IP20
Light Curtain Electric Parameter
Beam Space 10mm, 20mm, 40mm
Resolution 20mm, 30mm, 50mm
Beams 10mm: 8, 12, 16,...320
20mm: 4, 6, 8,...160
40mm: 4, 6, 8,...122
Protective Height Protective height H=(N-1)*beam space, N is beams
Light Wavelength 940nm
Sensing Distance 0.1~0.5m, 0.1~2m, 0.1~5m, 0.1~10m, 0.1~20m, 0.1-30m (Remark: please let us know when with reflectivity)
Sensing Method Through beam
Synchronization Wire-syn
Against Optical Interference 10000 Lux (angle>5")
Enclosure Material Aluminum alloy
Sectional Size 35 × 50mm
Protection Rate IP65
Vibration Resistance Frequency 10Hz-55Hz, amplitude 0.35±0.05mm, 20 times each in X, Y and Z direction


 

Bracket Options :






Controller Options 




*Remark :
  • Please check if light curtain control machine well before working and refer to step 4 to debug.
  • Avoid movement of safety light curtain casually;
  • The key of controller should be kept by professional engineers;
  • Engineers need to adjust the sensing distance and position of light curtain after changing machine model;
  • Power Supply should be cut off by professional operators when dissemble and maintain light curtain;
  • 100 million times, reaching the service life, or after three years of use, it should be replaced:
  • During use, be careful not to let workpieces, tools, wastes and other items collide with the photoelectric protection device.
  • Push reset button to re-start machine, if curtains connected with reset button, and machine stop after beam blocked.
 



 